<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>University of Tabriz</PublisherName>
				<JournalTitle>Tabriz Journal of Electrical Engineering</JournalTitle>
				<Issn>2008-7799</Issn>
				<Volume>52</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2022</Year>
					<Month>12</Month>
					<Day>22</Day>
				</PubDate>
			</Journal>
<ArticleTitle>nvestigation of the Effect of Wind Power Plant Control Modes on the Phenomenon of Fault-Induced Delayed Voltage Recovery(FIDVR)</ArticleTitle>
<VernacularTitle>nvestigation of the Effect of Wind Power Plant Control Modes on the Phenomenon of Fault-Induced Delayed Voltage Recovery(FIDVR)</VernacularTitle>
			<FirstPage>249</FirstPage>
			<LastPage>258</LastPage>
			<ELocationID EIdType="pii">15800</ELocationID>
			
<ELocationID EIdType="doi">10.22034/tjee.2023.15800</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>M.</FirstName>
					<LastName>Hajzaman</LastName>
<Affiliation>Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran, Iran</Affiliation>

</Author>
<Author>
					<FirstName>F.</FirstName>
					<LastName>Karbalaei</LastName>
<Affiliation>Faculty of Electrical Engineering, Shahid Rajaee Teacher Training University, Tehran, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>01</Month>
					<Day>11</Day>
				</PubDate>
			</History>
		<Abstract> In areas where the motor load is the predominant load, when the short circuit occurs, the speed of the motors decreases and their power reactive consumption increases, which causes some delays in voltage recovery after fault clearance. This delay can cause operation of protection systems and load shedding. Fault-Induced Delayed Voltage Recovery is a phenomenon in which the voltage level does not reach the pre-fault value immediately after the fault is cleared. If the Voltage recovery delay is significant, the wind power plant will be disconnected from the power system, which causes other problems in the power system. The purpose of this paper is to evaluate the effect of different wind power plant controls on voltage recovery delay. Wind power plant modeling is based on IEC61400-27-1 standard. Also in this paper the effect of location of wind power plant and the ability to Low Voltage Rid Through of wind power plant is considered. All the simulations are performed in DIgSILENT PowerFactory 2021 software.</Abstract>
			<OtherAbstract Language="FA"> In areas where the motor load is the predominant load, when the short circuit occurs, the speed of the motors decreases and their power reactive consumption increases, which causes some delays in voltage recovery after fault clearance. This delay can cause operation of protection systems and load shedding. Fault-Induced Delayed Voltage Recovery is a phenomenon in which the voltage level does not reach the pre-fault value immediately after the fault is cleared. If the Voltage recovery delay is significant, the wind power plant will be disconnected from the power system, which causes other problems in the power system. The purpose of this paper is to evaluate the effect of different wind power plant controls on voltage recovery delay. Wind power plant modeling is based on IEC61400-27-1 standard. Also in this paper the effect of location of wind power plant and the ability to Low Voltage Rid Through of wind power plant is considered. All the simulations are performed in DIgSILENT PowerFactory 2021 software.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Motor load</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Short circuit</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Control modes</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Wind power plant</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Low Voltage Rid Through</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://tjee.tabrizu.ac.ir/article_15800_6167f3d00c7265ff8cc8fe42b1097a34.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
